The carotid body is the main peripheral oxygen sensor, and in heart failure it contributes to sympathetic overdrive. How it senses oxygen is still unsettled. One hypothesis puts the sensor in mitochondrial complex IV and gives reactive oxygen species a role in the cascade. This preprint is the authors' attempt to measure carotid body mitochondria after heart failure, which they say had not been done.
They used rapid pacing in sheep to produce heart failure, and they measured the hypoxic ventilatory response and autonomic function before and after. Both the breathing response to low oxygen and sympathetic drive increased. Homogenates of whole carotid bodies were then used for high-resolution respirometry.
Complex IV oxygen affinity fell. The authors read the lower affinity as higher sensitivity to oxygen. Respiratory complexes were more abundant, but mitochondrial respiration did not change, and the rate of hydrogen peroxide production did not change either. Aconitase activity rose, and so did lipid peroxidation.
Metal and redox
Complex IV is the named enzyme, and oxygen affinity is the named property. The abstract does not measure heme a, heme a3, copper A, or copper B, so those sites stay unnamed. Hydrogen peroxide is the reactive oxygen species they quantified, and it did not rise. Aconitase activity rose. Aconitase uses a labile iron at a [4Fe-4S] cluster in the textbook enzyme, but this abstract reports activity only. It does not report the cluster. Lipid peroxidation rose on its own measurement, separate from the flat hydrogen peroxide rate.
What this does not show
The sensor hypothesis is still a hypothesis. Whole-organ homogenates are not a single cell type. A sheep pacing model is not a human trial. This account is the abstract of a preprint. It is not a treatment plan for heart failure or for the carotid body.